 Ask About This Product
N5000
E-mail Friend
Features
          Environment-friendly system to meet harmonic waves rule (IEEE 519-1992) by serialized multiplex drive
          High power factorand electric conversion efficiency
          High efficient operation by sensorless vector control
          Economic installation by slimming
          Easy maintenance by modularization
          Easy operation by one touch screen digital operator
          Remote console on user-friendly windows OS
 
 
   
   
   
   
     
Specification  
Voltage Class

3300V

3.3kV output capacity(kVA)

200

300

400

500

600

750

1000

1250

1500

1750

2000

2250

2700

3000

3500

4000

Rated output current(A)

35

53

70

88

105

132

175

219

263

307

350

394

473

525

619

707

Motor power output(kW)

155

245

325

410

490

620

835

1040

1270

1500

1710

1940

2250

2500

2800

3200

Voltage Class

4160V

4.16kV output capacity(kVA)

250

380

500

640

750

950

1250

1550

1900

2200

2500

2850

3400

3750

4400

5000

Rated output current(A)

35

53

70

89

105

132

174

216

264

306

347

396

472

525

619

707

Motor power output(kW)

205

310

410

530

630

790

1040

1310

1630

1900

2160

2460

2930

3240

3500

4000

Voltage Class

6600V

6.6kV output capacity(kVA)

400

600

800

1000

1200

1500

2000

2500

3000

3500

4000

4500

5400

6000

7000

8000

Rated output current(A)

35

53

70

88

105

132

175

219

263

307

350

394

473

525

619

707

Motor power output(kW)

330

495

675

835

1000

1270

1700

2130

2590

3020

3450

3930

4500

5000

5600

6400

Input

Main circuit

3-phase 3300V, 50/60Hz or 3-phase 6600V, 50/60Hz

Control circuit

3-phase 220V or 440V, 50Hz or 60Hz

Tolerance

Voltage : ¡¾10%, Frequency : ¡¾5%
Output

Output frequency(Hz)

50 or 60Hz

Overload ccapacity

120%, 60sec
Power factor of main power supply Approx. 95% or more at normal operating speed
Efficiency Approx. 96% (including transformer)
   
Control specification

Control Method

Sensorless vector control + Multilevel sinusoidal PWM

Frequency precision

¡¾0.5% of max. output frequency (Analog input)

Torque characteristics of load

Square torque load constant torque load

Acceleration deceleration time

0.1~3270sec (Depend on GD2 of motor and load)

Main control functions

Restart after instantaneous power failure, operation possible at instatnaneous input power failure (0-83ms, non-torque control), specific frequency evasion function, multiple Acc./Dcc. rate setting. soft stall

Main protective functions

Current limitm over current, over voltage, over load, under voltage, grand fault, CPU error, cooling fan, abnormal, control power abnormal

Data transmission

RS485/232/Modbus/ethernet, Profibus-DP(Oprion)

Operation board

Display

Color LCD graphic : color TFT touch screen 5" LCD

Method

Start, stop, reset fault

Signal interface

Analog

Input : 4 channel (DC 0~10V or DC 4~20mA)
Output : 4 channel (DC 0~10V or DC 4~20mA)

Digital

Input : 16 channel (Dry Contact)
Output : 8 channel (Dry Contact : AC 250V 5A or DC 30V 5A)

Input transformer

Temperature class H, Dry type, tapping range ¡¾5% for N5000 only

Construction

Protection degree of enclosure

IP20(IEC-529)

Panel construction

Free standing, free maintenance type, door hadle key type

Cooling

Air cooled by ventilation fans mounted on panel(IP40 without opening or closing of panel door)

Panel color

Munsell No. 5Y 7/1

Ambient conditions

Ambient temperature

0~40¡É

Humidity

Max 85%(No condensation)

Altitude

1000m above sea level or less

Vibration

0.5G or less at 10~50Hz

Installation

Indoor

Application

Fan, blower, pump, compressor extruder, mixer, turbine generators etc.

Standards

Electrical performance : IEC Components : KS
   
     
 